Dell EMC SC9000 Array Controller



Dell EMC SC9000 Array Controller price in hyderabad, chennai, telangana, india, kerala, bangalore, tamilnadu

  • Chassis :
  • Dimensions :
  • Height: 2U/87.3 mm (3.44 inches)
  • Width: 482.4 mm (18.98 inches) with rack latches; 444 mm (17.08 inches) without rack latches
  • Depth: 755.8 mm (29.75 inches) with bezel
  • Weight: 19.73 kg (43.5 lb) 
  • Rack support :ReadyRails II static rails for tool less mounting in 4-post racks with square or unthreaded round holes or tooled mounting in 4-post threaded hole racks
  • Connectivity :PCIe Gen 3 slots, 7 per controller, 4 full-height (cache card consumes one), 3 low profile, Any slot may be used for either front-end network or back-end expansion capacity connections 
  • Front-end network protocols : FC, iSCSI, FCoE (supports simultaneous multiprotocol) 
  • Max 32Gb FC ports : 32 per array (SFP+)
  • Max 16Gb FC ports : 40 per array
  • Max 8GbFC ports : 12 per array
  • Max 100Gb iSCSI ports :20 QSFP28 per array
  • Max 25Gb iSCSI ports : 20 SFP28 per array
  • Max 10Gb iSCSI ports : 32 SFP+ or BaseT per array iSCSI DCB IPv6
  • Max 10Gb FCoE ports : 12 per array 
  • Back end expansion protocols : 12Gb SAS (auto-negotiates to 6Gb) 
  • Max back-end expansion ports : 40 per array
  • Environmental Operating Conditions :
  • Temperature :Operating: 41º to 104ºF ( 5º to 40ºC )
  • Non-operating: -40º to 149ºF ( -40º to 65ºC )
  • Humidity :Operating: 10% to 80% (non-condensing)
  • Non-operating: 5% to 95% (non-condensing)
  • Product Configurations
  • Storage controller : SC9000 (2U chassis)
  • Controllers per array : 2 (active/active)
  • Operating system : Dell Storage Center 6.7 or greater
  • Processor : Dual 3.2GHz, 8-core Intel® processors per controller
  • Maximum system memory : 256GB per controller (512GB total per array)
  • Power :
  • Power/wattage: 2 hot-swappable 1100W 80 PLUS® Energy Star Platinum-certified power supplies 
  • Maximum output power: 1100 W 
  • Maximum input power: 1200 W 
  • Maximum input current: 12 A 
  • Maximum inrush current: 25A for 10 ms or less 
  • Nominal input voltage operating range: 100-240 VAC 
  • Nominal input frequency: 50/60 Hz
  • Maximum thermal output/heat dissipation: 4,760 BTU per hour (per controller) 
  • Fans : 6 hot-swappable fan modules
  • Regulatory :Product Safety, EMC and Environmental Datasheets, Dell Regulatory Compliance Home Page, Dell and the Environment
  • Scalability :Min/max drives : 6/1024 per array, more in federated systems
  • Max raw capacity : 6PB per array (SSD or HDD), more in federated systems
  • Expansion enclosures :
  • Mix and match from the following options:
  • Dell SC400: 12 x 3.5 drive bays, 12Gb SAS
  • Dell SC420: 24 x 2.5 drive bays, 12Gb SAS
  • Dell SC460: 60 x 3.5 drive bays, 12Gb SAS
  • Dell SC280: 84 x 3.5 drive bays, 6Gb SAS
  • Dell SC200: 12 x 3.5 drive bays, 6Gb SAS
  • Dell SC220: 24 x 2.5 drive bays, 6Gb SAS
  • Storage : Storage format : Block (SAN)
  • Storage media :SAS and NL SAS drives; different drive types, transfer rates and rotational speeds can be mixed in same system 
  • SSD: Write intensive and read intensive
  • HDD: 15K, 10K, 7.2K RPM
  • Functional :
  • Max SAN hosts: 500
  • Max initiator ports: 1000
  • Max LUN size: 500TB
  • Max number of LUNs: 2000
  • Max number of snapshots: 32,000
  • Max IOPS: 2,220,000*
  • Max IOPS:(with latency less than 1ms) 2,085,000
  • Max IOPS (80% reads, 20% writes): 502,000
  • Max throughput (reads): 33,000 MB/s
  • Max throughput (writes): 19,000 MB/s


Detailed Specification